• Dcs880-S02-1000-05X0, 4q 1000A 600HP, DC Motor Controller, DC Drive
  • Dcs880-S02-1000-05X0, 4q 1000A 600HP, DC Motor Controller, DC Drive
  • Dcs880-S02-1000-05X0, 4q 1000A 600HP, DC Motor Controller, DC Drive
  • Dcs880-S02-1000-05X0, 4q 1000A 600HP, DC Motor Controller, DC Drive
  • Dcs880-S02-1000-05X0, 4q 1000A 600HP, DC Motor Controller, DC Drive
  • Dcs880-S02-1000-05X0, 4q 1000A 600HP, DC Motor Controller, DC Drive

Dcs880-S02-1000-05X0, 4q 1000A 600HP, DC Motor Controller, DC Drive

Application: High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer
Output Type: Triple
Principle of Work: V/F Control Transducer
Switch Mode: PWM Control
Main Circuit Type: Current
Voltage of Power Supply: Low Voltage Variable-Frequency Drive
Samples:
US$ 8888/Box 1 Box(Min.Order)
| Request Sample
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Tianjin, China
to see all verified strength labels (8)

Basic Info.

Model NO.
DCS880-S02-1000-05X0
Link of Transformation
DC-DC
Nature of DC Power
Electrode Adjusting Speed
Function
Simple Type
Brand
Parker
Feedback Mode
Tacho Card
Quandrant
4 Quadrant
Ambient Temperature of Max
40 Degree
Max.Field Voltage
500V
Frequency
50Hz
Transport Package
Carton/Pallet/Wooden Box
Specification
29*31*45CM
Origin
China
HS Code
8543709990

Product Description

300 HP With 240 VAC Input | 600 HP With 480 VAC Input | DCS880 Series Open Chassis Enclosed Variable Frequency Drive (Regenerative, Reversing) | 208 - 240 VAC or 400 - 480 VAC 3 Phase Input | 500 VDC (0 - 500 VDC) DC Output | 990.0 Amps | DCS880-S02-1000-05X0

250 HP With 240 VAC Input | 500 HP With 480 VAC Input | DCS880 Series Open Chassis Enclosed Variable Frequency Drive (Regenerative, Reversing) | 208 - 240 VAC or 400 - 480 VAC 3 Phase Input | 500 VDC (0 - 500 VDC) DC Output | 812.0 Amps | DCS880-S02-0820-05X0

200 HP With 240 VAC Input | 400 HP With 480 VAC Input | DCS880 Series Open Chassis Enclosed Variable Frequency Drive (Regenerative, Reversing) | 208 - 240 VAC or 400 - 480 VAC 3 Phase Input | 500 VDC (0 - 500 VDC) DC Output | 673.0 Amps | DCS880-S02-0680-05X0

150 HP With 240 VAC Input | 300 HP With 480 VAC Input | DCS880 Series Open Chassis Enclosed Variable Frequency Drive (Regenerative, Reversing) | 208 - 240 VAC or 400 - 480 VAC 3 Phase Input | 500 VDC (0 - 500 VDC) DC Output | 490.0 Amps | DCS880-S02-0520-05X0

125 HP With 240 VAC Input | 250 HP With 480 VAC Input | DCS880 Series Open Chassis Enclosed Variable Frequency Drive (Regenerative, Reversing) | 208 - 240 VAC or 400 - 480 VAC 3 Phase Input | 500 VDC (0 - 500 VDC) DC Output | 429.0 Amps | DCS880-S02-0450-05X0

100 HP With 240 VAC Input | 200 HP With 480 VAC Input | DCS880 Series Open Chassis Enclosed Variable Frequency Drive (Regenerative, Reversing) | 208 - 240 VAC or 400 - 480 VAC 3 Phase Input | 500 VDC (0 - 500 VDC) DC Output | 340.0 Amps | DCS880-S02-0350-05X0

87.5 HP With 240 VAC Input | 175 HP With 480 VAC Input | DCS880 Series Open Chassis Enclosed Variable Frequency Drive (Regenerative, Reversing) | 208 - 240 VAC or 400 - 480 VAC 3 Phase Input | 500 VDC (0 - 500 VDC) DC Output | 292.0 Amps | DCS880-S02-0300-05X0

75 HP With 240 VAC Input | 150 HP With 480 VAC Input | DCS880 Series Open Chassis Enclosed Variable Frequency Drive (Regenerative, Reversing) | 208 - 240 VAC or 400 - 480 VAC 3 Phase Input | 500 VDC (0 - 500 VDC) DC Output | 244.0 Amps | DCS880-S02-0250-05X0

62.5HP With 240 VAC Input | 125 HP With 480 VAC Input | DCS880 Series Open Chassis Enclosed Variable Frequency Drive (Regenerative, Reversing) | 208 - 240 VAC or 400 - 480 VAC 3 Phase Input | 500 VDC (0 - 500 VDC) DC Output | 196.0 Amps | DCS880-S02-0200-05X0

37.5 HP With 240 VAC Input | 75 HP With 480 VAC Input | DCS880 Series Open Chassis Enclosed Variable Frequency Drive (Regenerative, Reversing) | 208 - 240 VAC or 400 - 480 VAC 3 Phase Input | 500 VDC (0 - 500 VDC) DC Output | 147.0 Amps | DCS880-S02-0150-05X0

30 HP With 240 VAC Input | 60 HP With 480 VAC Input | DCS880 Series Open Chassis Enclosed Variable Frequency Drive (Regenerative, Reversing) | 208 - 240 VAC or 400 - 480 VAC 3 Phase Input | 500 VDC (0 - 500 VDC) DC Output | 97.0 Amps | DCS880-S02-0100-05X0

20 HP With 240 VAC Input | 40 HP With 480 VAC Input | DCS880 Series Open Chassis Enclosed Variable Frequency Drive (Regenerative, Reversing) | 208 - 240 VAC or 400 - 480 VAC 3 Phase Input | 500 VDC (0 - 500 VDC) DC Output | 74.0 Amps | DCS880-S02-0075-05X0

15 HP With 240 VAC Input | 30 HP With 480 VAC Input | DCS880 Series Open Chassis Enclosed Variable Frequency Drive (Regenerative, Reversing) | 208 - 240 VAC or 400 - 480 VAC 3 Phase Input | 500 VDC (0 - 500 VDC) DC Output | 49.0 Amps | DCS880-S02-0050-05X0

7.5 HP With 240 VAC Input | 15 HP With 480 VAC Input | DCS880 Series Open Chassis Enclosed Variable Frequency Drive (Regenerative, Reversing) | 208 - 240 VAC or 400 - 480 VAC 3 Phase Input | 500 VDC (0 - 500 VDC) DC Output | 24.0 Amps | DCS880-S02-0025-05X0

7.5 HP With 240 VAC Input | 15 HP With 480 VAC Input | DCS880 Series Open Chassis Enclosed Variable Frequency Drive (Non-Regenerative, Non-Reversing) | 208 - 240 VAC or 400 - 480 VAC 3 Phase Input | 500 VDC (0 - 500 VDC) DC Output | 19.0 Amps | DCS880-S01-0020-05X0

DCS880 Series 405A 2 Quadrant Regenerative DC Thyristor Drive and Field Controller for 100V to 400V Supply.

Output Current: 405A Continuous.
Overload: 150% x 60 seconds every 15 minutes.
Typical Motor Output: Up to 217kW (291HP) at 460V DC for motor speed and torque control.

Dimensions: Frame Size H3: 460mm high x 270mm wide x317mm deep.
Weight: 25kg.

Terminals include:-
3 x Analogue Inputs (Selectable -20mA to 20mA, +/- 10V (11Bit +sign).
2 x Analogue Outputs (Selectable 0 to 20mA, 0 to 10V).
6 x Digital Inputs - Sink/ource, 1  can be used for PTC.
2 x Digital Inputs/Outputs - Programmable as outputs or pulse input/outputs.
3 x Relay Outputs.
Safe Torque Off (XSTO) anMain Contactor Shutdown (XSMC).
Drive to Drive Link (XD2D) and Built in Modbus EIA-485.
Encoder Differential or Single ended.
Tacho feedback included 5V +/- 8 to 270Vdc.
Input Output extention models and communications options are linked below or are available on request.

Input Current: 431A for Armature + up to 30A for Field.
Input Voltage: 100V to 480V three phase +-10% at 50/60Hz. +/- 15% short duration.
Input Fuse: 900A x High Speed Thyristor protection.
Input Choke: 1% to 4% line choke is required.

Auxiliary Supply: 115V or 230V single phase for electronics and 230V single phase for the Fan Supply.

Part number: DCS880-S01-0405-04.


Dcs880-S02-1000-05X0, 4q 1000A 600HP, DC Motor Controller, DC DriveDcs880-S02-1000-05X0, 4q 1000A 600HP, DC Motor Controller, DC DriveDcs880-S02-1000-05X0, 4q 1000A 600HP, DC Motor Controller, DC DriveDcs880-S02-1000-05X0, 4q 1000A 600HP, DC Motor Controller, DC DriveDcs880-S02-1000-05X0, 4q 1000A 600HP, DC Motor Controller, DC DriveDcs880-S02-1000-05X0, 4q 1000A 600HP, DC Motor Controller, DC Drive

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now