Dcs880-S01-0610-05X0, 610A, 400HP, Industrial DC Drive and Power Controllers

Product Details
Customization: Available
Application: High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer
Output Type: Triple
Still deciding? Get samples of US$ 8888/Box
Request Sample
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (8)
  • Dcs880-S01-0610-05X0, 610A, 400HP, Industrial DC Drive and Power Controllers
  • Dcs880-S01-0610-05X0, 610A, 400HP, Industrial DC Drive and Power Controllers
  • Dcs880-S01-0610-05X0, 610A, 400HP, Industrial DC Drive and Power Controllers
  • Dcs880-S01-0610-05X0, 610A, 400HP, Industrial DC Drive and Power Controllers
  • Dcs880-S01-0610-05X0, 610A, 400HP, Industrial DC Drive and Power Controllers
  • Dcs880-S01-0610-05X0, 610A, 400HP, Industrial DC Drive and Power Controllers
Find Similar Products

Basic Info.

Model NO.
DCS880-S01-0610-05X0
Switch Mode
PWM Control
Main Circuit Type
Current
Voltage of Power Supply
Low Voltage Variable-Frequency Drive
Link of Transformation
DC-DC
Nature of DC Power
Electrode Adjusting Speed
Function
Simple Type
Brand
Parker
Feedback Mode
Tacho Card
Quandrant
2 Quadrant
Ambient Temperature of Max
40 Degree
Max.Field Voltage
500V
Frequency
50Hz
Transport Package
Carton/Pallet/Wooden Box
Specification
29*31*45CM
Origin
China
HS Code
8543709990

Product Description

200 HP With 240 VAC Input | 400 HP With 480 VAC Input | DCS880 Series Open Chassis Enclosed Variable Frequency Drive (Non-Regenerative, Non-Reversing) | 208 - 240 VAC or 400 - 480 VAC 3 Phase Input | 500 VDC (0 - 500 VDC) DC Output | 595.0 Amps | DCS880-S01-0610-05X0

150 HP With 240 VAC Input | 300 HP With 480 VAC Input | DCS880 Series Open Chassis Enclosed Variable Frequency Drive (Non-Regenerative, Non-Reversing) | 208 - 240 VAC or 400 - 480 VAC 3 Phase Input | 500 VDC (0 - 500 VDC) DC Output | 465.0 Amps | DCS880-S01-0470-05X0

125 HP With 240 VAC Input | 250 HP With 480 VAC Input | DCS880 Series Open Chassis Enclosed Variable Frequency Drive (Non-Regenerative, Non-Reversing) | 208 - 240 VAC or 400 - 480 VAC 3 Phase Input | 500 VDC (0 - 500 VDC) DC Output | 393.0 Amps | DCS880-S01-0405-05X0

100 HP With 240 VAC Input | 200 HP With 480 VAC Input | DCS880 Series Open Chassis Enclosed Variable Frequency Drive (Non-Regenerative, Non-Reversing) | 208 - 240 VAC or 400 - 480 VAC 3 Phase Input | 500 VDC (0 - 500 VDC) DC Output | 312.0 Amps | DCS880-S01-0315-05X0

75 HP With 240 VAC Input | 150 HP With 480 VAC Input | DCS880 Series Open Chassis Enclosed Variable Frequency Drive (Non-Regenerative, Non-Reversing) | 208 - 240 VAC or 400 - 480 VAC 3 Phase Input | 500 VDC (0 - 500 VDC) DC Output | 267.0 Amps | DCS880-S01-0270-05X0

62.5 HP With 240 VAC Input | 125 HP With 480 VAC Input | DCS880 Series Open Chassis Enclosed Variable Frequency Drive (Non-Regenerative, Non-Reversing) | 208 - 240 VAC or 400 - 480 VAC 3 Phase Input | 500 VDC (0 - 500 VDC) DC Output | 222.0 Amps | DCS880-S01-0225-05X0

50 HP With 240 VAC Input | 100 HP With 480 VAC Input | DCS880 Series Open Chassis Enclosed Variable Frequency Drive (Non-Regenerative, Non-Reversing) | 208 - 240 VAC or 400 - 480 VAC 3 Phase Input | 500 VDC (0 - 500 VDC) DC Output | 178.0 Amps | DCS880-S01-0180-05X0

37.5 HP With 240 VAC Input | 75 HP With 480 VAC Input | DCS880 Series Open Chassis Enclosed Variable Frequency Drive (Non-Regenerative, Non-Reversing) | 208 - 240 VAC or 400 - 480 VAC 3 Phase Input | 500 VDC (0 - 500 VDC) DC Output | 133.0 Amps | DCS880-S01-0135-05X0

30 HP With 240 VAC Input | 60 HP With 480 VAC Input | DCS880 Series Open Chassis Enclosed Variable Frequency Drive (Non-Regenerative, Non-Reversing) | 208 - 240 VAC or 400 - 480 VAC 3 Phase Input | 500 VDC (0 - 500 VDC) DC Output | 89.0 Amps | DCS880-S01-0090-05X0

20 HP With 240 VAC Input | 40 HP With 480 VAC Input | DCS880 Series Open Chassis Enclosed Variable Frequency Drive (Non-Regenerative, Non-Reversing) | 208 - 240 VAC or 400 - 480 VAC 3 Phase Input | 500 VDC (0 - 500 VDC) DC Output | 64.0 Amps | DCS880-S01-0065-05X0

12.5 HP With 240 VAC Input | 25 HP With 480 VAC Input | DCS880 Series Open Chassis Enclosed Variable Frequency Drive (Non-Regenerative, Non-Reversing) | 208 - 240 VAC or 400 - 480 VAC 3 Phase Input | 500 VDC (0 - 500 VDC) DC Output | 44.0 Amps | DCS880-S01-0045-05X0

7.5 HP With 240 VAC Input | 15 HP With 480 VAC Input | DCS880 Series Open Chassis Enclosed Variable Frequency Drive (Non-Regenerative, Non-Reversing) | 208 - 240 VAC or 400 - 480 VAC 3 Phase Input | 500 VDC (0 - 500 VDC) DC Output | 19.0 Amps | DCS880-S01-0020-05X0

DCS880 Series 405A 2 Quadrant Regenerative DC Thyristor Drive and Field Controller for 100V to 400V Supply.

Output Current: 405A Continuous.
Overload: 150% x 60 seconds every 15 minutes.
Typical Motor Output: Up to 217kW (291HP) at 460V DC for motor speed and torque control.

Dimensions: Frame Size H3: 460mm high x 270mm wide x317mm deep.
Weight: 25kg.

Terminals include:-
3 x Analogue Inputs (Selectable -20mA to 20mA, +/- 10V (11Bit +sign).
2 x Analogue Outputs (Selectable 0 to 20mA, 0 to 10V).
6 x Digital Inputs - Sink/ource, 1  can be used for PTC.
2 x Digital Inputs/Outputs - Programmable as outputs or pulse input/outputs.
3 x Relay Outputs.
Safe Torque Off (XSTO) anMain Contactor Shutdown (XSMC).
Drive to Drive Link (XD2D) and Built in Modbus EIA-485.
Encoder Differential or Single ended.
Tacho feedback included 5V +/- 8 to 270Vdc.
Input Output extention models and communications options are linked below or are available on request.

Input Current: 431A for Armature + up to 30A for Field.
Input Voltage: 100V to 480V three phase +-10% at 50/60Hz. +/- 15% short duration.
Input Fuse: 900A x High Speed Thyristor protection.
Input Choke: 1% to 4% line choke is required.

Auxiliary Supply: 115V or 230V single phase for electronics and 230V single phase for the Fan Supply.

Part number: DCS880-S01-0405-04.


Dcs880-S01-0610-05X0, 610A, 400HP, Industrial DC Drive and Power ControllersDcs880-S01-0610-05X0, 610A, 400HP, Industrial DC Drive and Power ControllersDcs880-S01-0610-05X0, 610A, 400HP, Industrial DC Drive and Power ControllersDcs880-S01-0610-05X0, 610A, 400HP, Industrial DC Drive and Power ControllersDcs880-S01-0610-05X0, 610A, 400HP, Industrial DC Drive and Power ControllersDcs880-S01-0610-05X0, 610A, 400HP, Industrial DC Drive and Power Controllers

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier