• Three-Phase Monitoring Relay Cm-Pvs. 41s, L1-L2-L3=3X300-500VAC
  • Three-Phase Monitoring Relay Cm-Pvs. 41s, L1-L2-L3=3X300-500VAC
  • Three-Phase Monitoring Relay Cm-Pvs. 41s, L1-L2-L3=3X300-500VAC
  • Three-Phase Monitoring Relay Cm-Pvs. 41s, L1-L2-L3=3X300-500VAC
  • Three-Phase Monitoring Relay Cm-Pvs. 41s, L1-L2-L3=3X300-500VAC
  • Three-Phase Monitoring Relay Cm-Pvs. 41s, L1-L2-L3=3X300-500VAC

Three-Phase Monitoring Relay Cm-Pvs. 41s, L1-L2-L3=3X300-500VAC

Task: Following
Structure: Combination
Mathematical Model: Linear
Signal: Continuous
Function: Automatic Control
Condition: New
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Tianjin, China
to see all verified strength labels (8)

Basic Info.

Model NO.
CM-PVS. 41S
Customized
Non-Customized
Material
Plastic
Terminal Type
Screw Terminals
Pollution Degree
3
Max Operating Altitude Permissible
Without Derating 2000 M
Overvoltage Category
III
Transport Package
Carton
Specification
1KG
Trademark
FAMOUSE
Origin
Germany
HS Code
8536490090
Production Capacity
100000PCS/Year

Product Description

CM-PVS.41S Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3=3x300-500VAC

The CM-PVS.41S relay is from the CM three-phase monitors range. This relay operates with a rated control supply voltage / three-phase measuring voltage of  300-500 V AC and has a 2 c/o output with contacts rated at 250 V / 4 A. The CM-PVS.41S monitors the phase parameters over/undervoltage and phase failure. The corresponding threshold values are adjustable. Phase sequence monitoring as well as an ON or OFF tripping delay are selectable. The tripping delay is adjustable over a range of instantaneous to 30 s (0, 0.1-30 s). A sealable transparent cover for protection against unauthorized changes is available as accessory. The device offers screw connection technology with double-chamber cage connection terminals.

CM-PFS.S Three-phase monitoring relay 2c/o, L1-L2-L3=200-500VAC 50/60Hz

The CM-PFS.S relay is from the CM three-phase monitors range. This relay operates with a rated control supply voltage / three-phase measuring voltage of 200-500 V AC and has a 2 c/o output with contacts rated at 250 V / 4 A. The CM-PFS.S monitors the phase loss and phase sequence. The corresponding threshold values are fixed. The device offers screw connection technology with double-chamber cage connection terminals.

CM-PFE Phase sequence monitoring relay 1c/o, L1-L2-L3=208-440VAC

The CM-PFE relay is from the CM three-phase monitors range. This relay operates with a rated control supply voltage / three-phase measuring voltage of 208-440 V AC and has a 1 c/o output (closed circuit principle) with contacts rated at 250 V / 4 A. The CM-PFE monitors the phase loss and phase sequence. The corresponding threshold values are fixed. The relay is suitable for monitoring of three phase mains.

Multifunctional Three Phase monitoring relay CM-PVE  320-460VAC
CM-PVE Phase monitoring relay 1n/o, L1,2,3=320-460VAC


The CM-PVE relay is from the CM three-phase monitors range. This relay operates with a rated control supply voltage / three-phase measuring voltage of 320-460 V AC and has a 1 n/o output (closed circuit principle) with contacts rated at 250 V / 4 A. The CM-PVE monitors the phase loss, overvoltage and undervoltage. The corresponding threshold values are fixed. The relay is suitable for monitoring of three phase mains.

Dimensions
Product Net Width: 22.5 mm
Product Net Height: 78 mm
Product Net Depth / Length: 78.5 mm
Product Net Weight:  0.066 kg

Technical
Function: Phase failure detection
                Over- and undervoltage monitoring
Sub-Function: Phase loss
Sub-Function 2: 02 Over- and undervoltage (fixed)
Measuring Range: (L-L) 320 ... 460 V AC
Time Range: 500 ms start-up delay,  500 ms tripping delay
Rated Control Supply Voltage (Us): (L-L) 320 ... 460 V AC
Rated Frequency (f): Supply Circuit 50/60 Hz
Output: 1 n/o contact
Terminal Type: Screw Terminals
Rated Operational Current AC-12 (Ie): (230 V) 4 A
Rated Operational Current AC-15 (Ie): (230 V) 3 A
Rated Operational Current DC-12 (Ie): (24 V) 4 A
Rated Operational Current DC-13 (Ie): (24 V) 2 A
Rated Impulse Withstand Voltage (Uimp): Input Circuit 4 kV
Rated Insulation Voltage (Ui): Input Circuit / Output Circuit 400 V
Degree of Protection: Housing IP50,  Terminals IP20
Overvoltage Category: III
Pollution Degree: 3
Short-Circuit Protective Devices: Output Circuit NC - F Type Fuses 10 A, Output Circuit NO - F Type Fuses 10 A
Connecting Capacity: Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible 2x 1 ... 1.5 mm²
Rigid 2x 0.75 ... 1.5 mm²
Tightening Torque: 0.6 ... 0.8 N·m
Wire Stripping Length: 10 mm

Three-Phase Monitoring Relay Cm-Pvs. 41s, L1-L2-L3=3X300-500VACThree-Phase Monitoring Relay Cm-Pvs. 41s, L1-L2-L3=3X300-500VACThree-Phase Monitoring Relay Cm-Pvs. 41s, L1-L2-L3=3X300-500VACThree-Phase Monitoring Relay Cm-Pvs. 41s, L1-L2-L3=3X300-500VACThree-Phase Monitoring Relay Cm-Pvs. 41s, L1-L2-L3=3X300-500VACThree-Phase Monitoring Relay Cm-Pvs. 41s, L1-L2-L3=3X300-500VAC
 